Palm's Instruments Division
Electroless Nickel Controllers:
Model 1101 Electroless Nickel
Controller
The
Model 1101 is a state-of-the-art, automatic controller
for electroless nickel plating baths. It will maintain the bath's
strength within very close limits with a minimum of operator
assistance. The controller is very easy to use and may be adapted
for most electroless nickel solutions. The Model 1101
monitors the bath's concentration, pH and temperature. When needed,
it makes additions of nickel and hypophosphite replenishers and
neutralizers to keep the solution within the proper operating
range. It also keeps a record of the bath and its age, and the
volume of chemicals used and remaining. These records can be
used to track costs and profitability. In addition, its analyses
can be transmitted to a printer or personal computer by RS-232
data transfer. With the proper software, the data can be analyzed
to provide statistical process control and product certification.
The controller also has audible, high and low level alarms to
alert the operator to out-of limit conditions. The Model 1101
contains a custom designed, microprocessor to allow close control,
maximum flexibility, advanced record keeping, and statistical
data handling. It is very user friendly. It prompts the operator
to enter any required information through a menu selection process.
Set points, alarm levels, bath volume, concentration and age,
and sampling and addition times are all adjustable. The user
can easily change them to account for changes in bath chemistry
or volume. Automatic bath control can provide many benefits for
the electroless nickel plater. It can increase production by
maintaining the bath's operating parameters within close control
and thus providing the maximum deposition rate. The baths life
is also extended by operating the solution at its optimum condition.
This also helps provide consistent and quality deposits and reduces
rejects. The better records produced by a controller also help
to better manage the process and to better track costs.
PACKAGES
|
1101-B |
Nickel controller, sample pump,
50' Hi temperature sample hose, sample pick-up tube. Replenishment
pumps are not included with this package. |
|
1101-R |
Same as 1101-B with the addition
of a Nickel/Hypo replenishment pump, 2 replenisher pickup tubes,
and 200' of 1/2" tubing. |
|
1101-P |
Same as the 1101-R with the addition
of pH neutralizer pump, 1 pH pickup tube, and 100' of 3/8"
tubing. |
|
1101-C |
Same as the 1101-P with an additional
pump for concentrate additions, 1 pickup tube, and 100' of 3/8"
tubing. |
|
1101-S |
Same as the 1101-P with the addition
of SPC software, cabling, and interface. |
SPECIFICATIONS
|
Control Modes: |
Automatic: Closed Loop control with
automatic addition of Ni replenisher, hypo, and pH adjuster.
Manual: A manual pump addition can be made with a displayed time. |
|
Control Adjustments: |
One point and two point calibrations
can be made for both the nickel metal analysis and pH.
A one point trim can be made to the cell temperature. |
|
Control Setpoints: |
Tank volume, pump outputs, percentage
addition, set point of addition, high Ni pH temperature, low
Ni pH drum volumes, pH add point. |
|
Control Limits: |
Nickel metal 4.0 g/l - 7.0 g/l
pH: 4.0 - 7.0 pH
Temperature: 0 - 100 Deg C |
|
Alarm Modes: |
Nickel metal high, nickel metal
low, pH high, pH low, cell temperature high, replenisher drum
volume low. |
|
Instrument Power: |
Controller - 110/220 Vac @ 15 Amps
Printer Output: Serial 1200 baud 50' max. cable length.
SPC Output: RS-232 125 max. cable length.
LCD Display: 4 x 20 backlite super twist LCD |
|